Damaged extension cord osha
WebAug 23, 2024 · torn, frayed, or exposed wires tangled and/or overcrowded wires loose electrical connections substandard insulation malfunctioning electrical equipment … Web1. Develop and maintain a safety and health program to provide guidance for safe operations. 2. If high voltage lines are not de-energized, visibly grounded, or protected by insulating barriers, equipment operators must maintain a minimum distance of 10 feet between their equipment and the electrical distribution or transmission lines. 3.
Damaged extension cord osha
Did you know?
WebApr 12, 2010 · April 12, 2010 Letter # 20090606-9144 Re: Whether an employer can repair an extension cord under 29 CFR 1926, Subpart K. Question: Under what circumstances … Web4600 Health Sciences Rd. • Irvine, CA 92697 • (949)-824-6200 • www.ehs.uci.edu • [email protected] DO NOT use surge protectors or power strips for extra outlets, as an “ON/OFF” switch, or as an extension cord to reach appliances or equipment. Check indicator on surge protectors periodically to ensure “protected” light is “ON ...
WebFeb 11, 2024 · It shouldn’t happen, but it does. Even heavy-duty extension cords become damaged. Because they can be expensive, you may be asked to make a repair, rather … WebThe only non-flexible parts of a cord are the plugs. This makes them vulnerable to knocks, and crushing and flexing damage when, for example, they are dropped, run over by …
WebJun 21, 2024 · Overload cords with more than the proper electrical load. Run extension cords through doorways, holes in ceilings, walls or floors. Daisy chain, or connect, multiple power strips together. Move, bend or modify any of the extension cord plug’s metal parts. Force a plug into an outlet. Drive over an extension cord. WebPortable equipment must be handled in a manner that will not cause damage. Flexible electric cords connected to equipment may not be used for raising or lowering the …
WebMar 18, 2024 · Most manufacturers recommend that your extension cord be replaced after three to five years of regular use. And, is inspected frequently. Since they are made up of many different materials such as rubber, plastic, or metal, they are susceptible to damage if overused or misused. Damaged cords can lead to electrocution or house fires. fnf super hryWebApr 11, 2024 · Extension cords must be treated with care and checked regularly for damage or deterioration. The cord itself should never be pulled to disconnect it from an … greenville pa chevy dealershipWebOSHA has several standards on electricity, but none of them cover electrical tape and using it to mend damaged power cables. With that said, a spokesperson for OSHA recently advised against this practice, citing Section 1926.401 (a), which requires all electrical conductors and equipment to be approved. The spokesperson ads that applying too ... greenville pa coffee shopWebFeb 11, 2024 · Let’s review the correct way to repair electrical cords. The first obvious step is often overlooked. Unplug the cord and take control of both ends. Splices: Cut back only enough of the outer and inner insulation to make the repair. Keep in mind that the color-coded wires on one side need to be connected to the like-colored wires on the other. fnf super sonic smackdown gamebananaWebBecause these cords are often exposed, flexible, and unsecured, they are highly susceptible to damage and misuse that can result in significant hazards. Following … fnf super sonic cdWebRule 4. Do not secure extension cords to walls or ceilings using metal nails or staples. Metal fasteners can easily damage the relatively soft flexible jacket of the cord. Slight impacts, pinching or bending can damage the cord. Even pulling on the cable can wear through the jacket accidentally. fnf super sonic skinWebJul 1, 2016 · Extension cords are manufactured with a soft jacket to offer flexibility to the power cord, which makes them susceptible to the damage. The damage can happen during initial installation or during use. greenville pa from my location